rfid
Battery charging cabinet 8/10 Premium, fire-resistant 60 min, lockEX 2.0
Fire-resistant and explosion-proof safety cabinet for storing and charging lithium-ion batteries.
- Safe charging of 18 batteries simultaneously – 2 power strips with 18 sockets
- Equipped with an early warning system, automatic power cut-off, and technical ventilation, effectively minimizing the risk of fire
- Power is disconnected if smoke is detected
- Full integration with existing safety infrastructure
- TÜV NORD certification confirms the highest level of safety
- Tested in accordance with VDMA 24994 specification
Premium 8/10 Cabinet 60 min is the ideal solution for safely charging and storing lithium-ion batteries and electrical devices. It guarantees fire protection for 60 minutes (confirmed in accordance with DIN EN 1363-1) and early hazard detection thanks to intelligent smoke sensors. Built from non-combustible and fire-resistant materials.
Battery cabinet equipment:
- electronic smoke sensor (without audible alarm),
- technical ventilation,
- automatic power disconnection in case of overheating, door opening, or smoke detection,
- voltage-free output for integration with an external fire alarm system,
- 12 V connector for connecting an alarm unit,
- 2 power strips with 9 sockets each (3500 W, 16 A),
- lockEX technology with controlled pressure reduction – a special spring lock prevents the door from opening in the event of an explosion,
- lockable doors with a solid lock and hinges,
- advanced protection against fire and smoke – fire-resistant seals, a smoke ingress prevention system, thermocouples in the ventilation openings,
- a fan dispersing heat during the charging process,
- the ventilation openings have been secured with thermocouples
Application: ideal for use inside production halls, warehouses, workshops, service stations, and anywhere safe charging of lithium-ion batteries is required.

The lockEX 2.0 cabinets for lithium-ion batteries and accumulators have been tested in accordance with the current VDMA testing method, dedicated to hazards related to Li-ion technology. The test confirms that the solution meets the highest fire safety standards and addresses real risks occurring in industry.
What does the VDMA test concern?
- simulation of ignition and the so-called thermal runaway of Li-ion batteries,
- verification of whether fire, temperature, and fire gases remain inside the cabinet,
- assessment of the protection of the surroundings, infrastructure, and personnel.
| Function / equipment | Basic | Premium | Premium Plus |
|---|---|---|---|
| Smoke sensor (alarm) | ✔ | ✔ | ✔ |
| Fan dissipating heat from the charging process | ✔ | ✔ | ✔ |
| Automatic charging stop when the door is opened (door contact) | ✔ | ✔ | ✔ |
| Power disconnection when the temperature rises | ✔ | ✔ | ✔ |
| Power disconnection upon smoke detection | – | ✔ | ✔ |
| 12 V output for integration with external devices | – | ✔ | ✔ |
| Remote SMS notifications | – | – | ✔ |
| Remote notifications via mobile app | – | – | ✔ |
| External digital cabinet status display | – | – | ✔ |
| Compliance with VDMA 24994 (Li-ion battery fire test) | Tested | Tested | Certified |
Product Details
- Reference
- 103-4-NCE-1043
- Color
- pomarańczowy
- Weight
- 146 kg
- Internal dimensions (LxWxH)
- 73 x 53 x 88 cm
- Certificates
- TÜV NORD (program M02/22), DIN EN 1363-11
- Door construction
- dwuskrzydłowe
- Number of shelves
- 4 szt.
- External dimensions (LxWxH)
- 89 x 66 x 115 cm
- Shelf load capacity
- 30 kg